J. Le Graet, A. Secroun, M. Tourneur-Silvain, W. Gillard, N. Fourmanoit, S. Escoffier, E. Kajfasz, S. Kermiche, B. Kubik, J. Zoubian, S. Andreon, M. Baldi, S. Bardelli, P. Battaglia, D. Bonino, E. Branchini, M. Brescia, J. Brinchmann, A. Caillat, S. Camera, V. Capobianco, C. Carbone, J. Carretero, S. Casas, M. Castellano, G. Castignani, S. Cavuoti, A. Cimatti, C. Colodro-Conde, G. Congedo, C. J. Conselice, L. Conversi, Y. Copin, F. Courbin, H. M. Courtois, A. C. da Silva, J. Dinis, M. Douspis, F. Dubath, C. A. J. Duncan, X. Dupac, S. Dusini, A. Ealet, M. Farina, S. Farrens, F. Faustini, S. Ferriol, M. Frailis, E. Franceschi, S. Galeotta, B. R. Gillis, C. Giocoli, F. Grupp, S. V. H. Haugan, W. A. Holmes, F. Hormuth, A. Hornstrup, P. Hudelot, K. Jahnke, M. Jhabvala, A. Kiessling, M. Kilbinger, R. Kohley, H. Kurki-Suonio, P. B. Lilje, V. Lindholm, I. Lloro, G. Mainetti, D. Maino, E. Maiorano, O. Mansutti, O. Marggraf, K. Markovic, N. Martinet, F. Marulli, R. Massey, E. Medinaceli, S. Mei, M. Meneghetti, G. Meylan, M. Moresco, L. Moscardini, S. M. Niemi, J. W. Nightingale, C. Padilla, S. Paltani, F. Pasian, K. Pedersen, V. Pettorino, S. Pires, G. Polenta, M. Poncet, L. A. Popa, F. Raison, A. Renzi, J. D. Rhodes, G. Riccio, E. Romelli, M. Roncarelli, E. Rossetti, R. Saglia, D. Sapone, B. Sartoris, J. A. Schewtschenko, M. Schirmer, G. Seidel, M. D. Seiffert, C. Sirignano, G. Sirri, L. Stanco, J. Steinwagner, P. Tallada-Crespí, D. Tavagnacco, A. N. Taylor, H. I. Teplitz, I. Tereno, R. Toledo-Moreo, F. Torradeflot, I. Tutusaus, L. Valenziano, T. Vassallo, A. Veropalumbo, Y. Wang, J. Weller
Abstract
We introduce a fast method to measure the conversion gain in complementary metal-oxide-semiconductor active pixel sensors, which accounts for nonlinearity and interpixel capacitance (IPC). The standard "mean-variance" method is biased because it assumes that pixel values depend linearly on the signal, and existing methods to correct for nonlinearity still introduce significant biases. While current IPC correction methods are prohibitively slow for a per-pixel application, our new method uses separate measurements of the IPC kernel to calculate the gain almost instantaneously. Using test data from a flight detector of the ESA Euclid mission, the IPC correction recovers the results of slower methods with 0.1% accuracy. The nonlinearity correction ensures that the estimated gain is independent of signal, correcting a bias of more than 2.5%.
Keywords
instrumentation: detectors / methods: data analysis / methods: numerical / methods: statistical
Notes
This paper is published on behalf of the Euclid Consortium.
Astronomy & Astrophysics
Volume 705, Article Number A138, Number of pages 12
2026 January









